Orion ATLAS EQ-G User Manual Page 19

  • Download
  • Add to my manuals
  • Print
  • Page
    / 27
  • Table of contents
  • BOOKMARKS
  • Rated. / 5. Based on customer reviews
Page view 18
19
9. Technical Specifications
Mount: German equatorial
Tripod: Steel
Weight: 54lbs.
Counterweights: Quantity 2, 11 lbs. each
Polar axis latitude adjustment: 10° to 65°
Polar axis finder scope: Included, illuminator built
into mount
Motor drives: Dual-axis, GoTo comput-
erized, internally housed
Operation: Northern or Southern
hemisphere
Power requirement: 12V DC, 2A (tip positive)
Motor type and resolution: Microstep driven 1.8°
stepper motors
Resolution: 0.144 arc sec (or
9,024,000 steps/rev)
Gear ratio: 705
#7795 Dual-Axis hand controller
Slew speeds: Guiding speed
4x
8x
32x
64x
800x
Guiding speeds: 2x / 1.75x / 1.5x / 1.25x
sidereal rate
Tracking rates: sidereal, lunar, solar
Tracking mode: R.A. tracking
#7796 GoTo hand controller
Slew speeds: Rate 0 = 1.5x
Rate 1 = 2x
Rate 2 = 8x
Rate 3 = 16x
Rate 4 = 32x
Rate 5 = 64x
Rate 6 = 400x
Rate 7 = 500x
Rate 8 = 600x
Rate 9 = 800x (3.4°/sec)
Autoguiding rates: 2x / 1.75x / 1.5x / 1.25x
sidereal rate
Tracking rates: Sidereal (default), lunar,
solar, PEC + sidereal
Tracking modes: R.A. tracking
Alignment method: One-star alignment, two-
star alignment, three-star
alignment
Database: 25 user-defined objects,
complete M, NGC, and IC
catalogs.
Total 13,436 objects
Pointing accuracy: Up to 1 arcminute with
cone error calibration, up
to 15 arcminutes without
cone error calibration.
This device complies with Part 15 of the FCC Rules. Operation
is subject to the following two conditions: (1) this device nay
not cause harmful interference, and (2) this device must
accept any interference received, including interference that
may cause undesired operation.
Changes of modifications not expressly approved by the party
responsible for compliance could void the user’s authority to
operate the equipment.
Note: This equipment has been tested and found to comply
with the limits for a Class B digital device, pursuant to Part
15 of the FCC Rules. These limits are designed to provide
rea son able protection against harmful interference in a resi-
dential installation. This equipment generates, uses and can
radiate radio frequency energy and, if not installed and used in
accordance with the instructions, may cause harmful interfer-
ence to radio communications. However, there is no guarantee
that interference will no occur in a particular installation. If this
equipment does cause harmful interference to radio or televi-
sion reception, which can be determined by turning the equip-
ment off and on, the user is encouraged to try to correct the
interference by one or more of the following measures:
-Reorient or relocate the receiving antenna.
-Increase the separation between the equipment and
receiver.
-Connect the equipment into an output on a circuit different
from that to which the receiver in connected.
-Consult the dealer or an experienced radio/TV technician
for help.
A shielded cable must be used when connecting a peripheral
to the serial ports.
Page view 18
1 2 ... 14 15 16 17 18 19 20 21 22 23 24 25 26 27

Comments to this Manuals

No comments